Filter Results By:

Products

Applications

Manufacturers

Data Acquisition Systems

sense, log and store information. AKA: DAS

See Also: Data Acquisition, PCI Data Acquisition, DAQ


Showing results: 496 - 510 of 853 items found.

  • PXI 2 Amp MUX, Single 64-Channel 1-Pole

    40-635-001 - Pickering Interfaces Ltd.

    The 40-635 2 Amp Multiplexer module is available in 9 standard configurations as well as 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.

  • PXI 2 Amp MUX, Single 8-Channel 4-Pole

    40-635-103 - Pickering Interfaces Ltd.

    The 40-635 2 Amp Multiplexer module is available in 9 standard configurations as well as 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.

  • PXI 2 Amp MUX, Single 8-Channel 8-Pole

    40-635-004 - Pickering Interfaces Ltd.

    The 40-635 2 Amp Multiplexer module is available in 9 standard configurations as well as 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.

  • Data Acquisition - 3U 3-Slot

    DAQ-33CP0G - North Atlantic Industries

    is a preconfigured rugged system with a high-performance, low power ARM® Cortex®-A9 processor. It is ideally suited to support a multitude of military/aerospace data acquisition applications that require high-density, multichannel programmable ARINC 429/575; Dual-Redundant, Quad Channel MIL-STD-1553B; CANBus (2.0 A&B or J1939); A/D Conversion; RTD Measurement; RS-232/422/485 Serial Communications Dual-Port Gig-E Ethernet.

  • PXI High Density Multiplexer, 20-Bank, 4-Channel, 1-Pole (SP4T)

    40-615A-013 - Pickering Interfaces Ltd.

    The 40-615A-013 is a 20-bank, 4-channel, 1-pole (SP4T) MUX and is part of our range of PXI high density reed-relay based multiplexer modules. These feature a wide range of switching configurations and are especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector.

  • Dynamic Gravity Meter

    TAGS-7 - Micro-g LaCoste

    TAGS-7 represents the latest development in a long line of LaCoste-based airborne gravity systems, stretching back to the first successful airborne gravity flights in 1958 and building on the success of the TAGS System. For over 50 years, LaCoste gravimeters have acquired hundreds of thousands of line kilometers of gravity data during academic, government, and commercial surveys. TAGS-7 blends the latest in GPS and data acquisition technology with the solid foundation of the LaCoste dynamic gravimeter.TAGS-7 is an upgrade to the TAGS-6 gravity meter, and is designed specifically for airborne operations. The system incorporates a time-tested, low-drift, zero-length-spring gravity sensor mounted on a gyro-stabilized gimbal platform. The sensor has a worldwide gravity measuring range (no reset necessary) of 500,000 milliGals.

  • 2-Channel 200 MHz A/D with 766 DDCs, Kintex UltraScale FPGA - PCIe

    Model 78865 - Pentek, Inc.

    Model 78865 is a member of the JadeTM family of high-performance x8 PCIe boards. The Jade architecture embodies a new streamlined approach to FPGA-based boards, simplifying the design to reduce power and cost, while still providing some of the highest- performance FPGA resources available today. Designed to work with Pentek’s new NavigatorTM Board Support package, the combination of Jade and Navigator offersusers an efficient path to developing and deploying FPGA-based data acquisition and processing applications. The 78865 is a two channel data converter with a total of 766 programmable DDCs(digital downconverters). It is suitable for connection to HF or IF ports of a communications or radar system. Its built-in data capture feature offers an ideal turnkey solution for extremely high-channel-count systems.

  • PXI Dual 12x8 Matrix, 2 Pole Switching

    40-522-022 - Pickering Interfaces Ltd.

    Medium density PXI dual 12x8, 2-pole matrix - it is also available in reed relay formats of 2-pole and 1-pole screened (see "also in this range" on right). The screened version is suitable for switching signals up to 50MHz. Typical applications include signal routing in ATE and data acquisition systems. The two banks may be used for operating a 4-wire measurement system (bank-1 for source, bank-2 for measure). Larger matrices may be constructed by daisy chaining the common signals from multiple PXI Modules.

  • PXI Single 44x4 Matrix, 2 Pole Switching

    40-523-022 - Pickering Interfaces Ltd.

    Medium density PXI dual 44x4, 2-pole matrix - it is also available in reed relay formats of 1-pole and 1-pole screened (see "also in this range" on right). The screened version is suitable for switching signals up to 50MHz. Typical applications include signal routing in ATE and data acquisition systems. The two banks may be used for operating a 4-wire measurement system (bank-1 for source, bank-2 for measure). Larger matrices may be constructed by daisy chaining the common signals from multiple PXI Modules.

  • PXI Single 46x4 Matrix, 1 Pole Switching

    40-524-021 - Pickering Interfaces Ltd.

    Medium density PXI dual 46x4, 1-pole matrix - it is also available inreed relay formats of 2-pole and 1-pole screened (see "also in this range" on right). The screened version is suitable for switching signals up to 50MHz. Typical applications include signal routing in ATE and data acquisition systems. The two banks may be used for operating a 4-wire measurement system (bank-1 for source, bank-2 for measure). Larger matrices may be constructed by daisy chaining the common signals from multiple PXI Modules.

  • IC-3120, 1.91 GHz Intel Atom Quad-Core Processor, 2-GigE Port Industrial Controller

    784959-01 - NI

    The IC‑3120 is a compact and rugged industrial controller that withstands the harsh environments common in automation, supervisory control, distributed control, and industrial embedded OEM applications. The IC‑3120 offers two Gigabit Ethernet ports with Power over Ethernet (PoE) technology, FPGA-based I/O capabilities, and network connectivity for distributed control applications. The advanced features include the ability to synchronize image inspection results with industrial I/O and configure hardware-timed network triggers to trigger camera acquisition, motion control, or data acquisition. You can use the advanced FPGA personality that is shipped with the system or customize the FPGA functionality using the LabVIEW FPGA Module.

  • ARINC 664 ProView Software

    ProView - Innovative Control Systems, Inc.

    ProView is a low cost, ARINC 664 bus reader / logger / analyzer designed specifically for the Rockwell-Collins specific ARINC 664 implementation that works well, is very low cost, and no external capture hardware is required. Innovative Control Systems, Inc. is pleased to announce the release of our new ARINC 664 ProView logging analyzer software which allows you to perform live display, recording, playback, and Export (to CSV file) of Rockwell Collins specific ARINC 664 data on a suitable Microsoft® Windows® operating system based laptop or PC. No additional capture hardware is required for this analyzer, just an available Ethernet port on the computer and you are able to analyze your data. The software can also be used to create configuration files for our FTSIU flight test data acquisition interfaces as well as playback flight test data sets recorded by that equipment.

  • Temperature Data Acquistion

    THERMES-USB RF - Physitemp Instruments

    Physitemp’s original Thermes high accuracy ISA based data acquisition system has been redesigned to create a more versatile USB model. The new system requires no internal connections to your computer and simply connects via an external USB port on your laptop or desktop computer. Two versions of the data acquisition system are available. The standard version, THERMES USB, is connected to your computer USB port. The wireless version - THERMES USB WFI, can be either directly connected to a USB port or, with the included wireless receiver, positioned up to 100 feet from the host computer. Each unit will accommodate up to 7 type T thermocouple sensors and multiple Thermes units may be connected to the same computer for more thermocouple inputs. A high accuracy electronic cold junction compensation circuit maintains typical system accuracy of ±0.2°C over an ambient temperature range of 15 to 35°C. Individual offsets may be added to each input in software to facilitate individual calibration of each channel. For information on our wide selection of Type T Thermocouple temperature probes.

  • PXI Ultra High Density 64x2 2-Pole Matrix

    40-533B-032 - Pickering Interfaces Ltd.

    The 40-533B ultra high density matrix module is configured as 64x4 or 64x2 and is available in a choice of 1-pole and 2-pole reed relay formats. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability sputtered Ruthenium reed relays, offering >109operations to give maximum switching confidence with long life and stable contact resistance.

  • PXI Ultra High Density 64x2 1-Pole Matrix

    40-533B-031 - Pickering Interfaces Ltd.

    The 40-533B ultra high density matrix module is configured as 64x4 or 64x2 and is available in a choice of 1-pole and 2-pole reed relay formats. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability sputtered Ruthenium reed relays, offering >109operations to give maximum switching confidence with long life and stable contact resistance.

Get Help